SCHNEIDER ELECTRIC VW3A4553
SCHNEIDER ELECTRIC VW3A4553 € 129,50 excl. btw · € 155,40 incl. btw
Terug naar producten
SKF 2219 M
SKF 2219 M € 368,50 excl. btw · € 442,20 incl. btw

PEPPERL+FUCHS KFD2-SOT-EX2 034065

SKU: 2608281060

PEPPERL+FUCHS KFD2-SOT-EX2 034065

€ 152,50 excl. btw · € 183,00 incl. btw

1 op voorraad

1 op voorraad

Levering en verzendinformatie · Retourneren

Twijfel je of dit artikel past? Vraag ons om hulp en vermeld het merk en artikelnummer.

Betaalmethode:

Specificatie

Gewicht2,00 kg
Verpakkingshoeveelheid1 Unit(s)
EenheidUnit(s)
MerkPEPPERL+FUCHS
CategorieSafety Automation
OmschrijvingIntrinsic Safety Barrier
MPNKFD2-SOT-EX2 034065
Andere aanduidingenKFD2-SOT-EX2 034065, KFD2-SOT-EX2034065, KFD2SOTEX2 034065, KFD2SOTEX2034065
Artikelnummer fabrikantKFD2SOTEX2 034065

Oudenbosch

Vandaag

Nederland

België 

1-2 dagen
1-2 dagen

Omschrijving

Pepperl+Fuchs KFD2-SOT-EX2 Switch Amplifier Description The KFD2-SOT-EX2 is a high-reliability, 2-channel switch amplifier from Pepperl+Fuchs’ K-System. This isolated barrier is engineered for intrinsic safety applications, allowing it to safely drive devices like solenoid valves, I/P converters, or LED indicators within a hazardous area. It accepts inputs from NAMUR sensors or dry contacts and provides a galvanically isolated transistor output to the safe area. Key features include line fault detection (LFD) and a reversible mode of operation for maximum flexibility. Specifications Type: Switch Amplifier / Isolated Barrier Channels: 2 Input Signal: NAMUR, dry contact Output Signal: Transistor output Supply Voltage: 20 V DC to 35 V DC Ambient Temperature: -20 to 60 deg C (-4 to 140 deg F) Mounting: DIN Rail Connection: Screw terminals Label Info Part No: 034065 ATEX Certification: PTB 00 ATEX 2080 Safety Marking: II (1) G D [Ex ia] IIC Application Ideal for use in process automation, chemical, petrochemical, and pharmaceutical industries where control signals must be sent into potentially explosive atmospheres. It ensures that the energy level of the signal entering the hazardous area is too low to cause an ignition. Country of Origin Made in Singapore. CO2 Impact By purchasing this reused component, you are contributing to a circular economy and avoiding approximately 6.0 kg of CO2 emissions that would be generated from manufacturing a new one. Availability This item is in stock and ready for immediate dispatch. Order now from profideals for expert support and fast delivery. FAQ What is the primary function of the KFD2-SOT-EX2 in a control system?Its primary function is to act as an intrinsically safe (IS) isolated barrier. It takes a low-power, non-IS signal from a control system (like a PLC) and converts it into an IS signal that can safely operate a device (like a solenoid valve) in a hazardous (potentially explosive) area without risk of ignition. How do I configure the output mode for normally open (NO) or normally closed (NC) operation?The output mode can be reversed via switches on the side of the unit. This allows you to configure the output to be energized (switched on) or de-energized (switched off) when the input is active, accommodating both NO and NC logic. What does the Line Fault Detection (LFD) feature indicate and how is it enabled?Line Fault Detection monitors the field circuit for open-circuit (wire break) or short-circuit conditions. If a fault is detected, a dedicated LFD output is activated, and a red LED on the front of the unit will blink. This feature is enabled via a switch on the side of the module. Last Update: Friday, March 13, 2026 profideals is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners.